MEDICAL ISOLATION
TRANSFORMERS

Specially engineered for hospitals, operation theatres, ICUs, cath labs, and critical healthcare facilities. Delivers complete galvanic isolation with ultra-low leakage current for maximum patient and operator safety.

Medical Isolation Transformer

SPECIFICATIONS

KVA Rating
1 KVA to 100 KVA
Core Type
Low-Loss CRGO Core
Copper Windings
Input
Single Phase / Three Phase
230 V / 415 V
Insulation Class
Class H – 180°C
Leakage Current
< 0.5 mA (IEC 61558)
Temperature Rise
80°C Rise
Phase
Single Phase / Three Phase
Standard
IEC 61558-2-15
Indoor Installation

KEY FEATURES

01
Ultra-Low Leakage Current
Achieves < 0.5 mA leakage, minimizing electric shock risk.
02
Complete Galvanic Isolation
Full electrical separation between utility and medical equipment.
03
Enhanced Patient Protection
Protects patients connected to devices from hazardous touch voltages.
04
Superior EMI/RFI Suppression
Minimizes electromagnetic interference affecting sensitive equipment.
05
High Reliability Construction
Low-loss CRGO cores, copper windings, Class H Insulation.
06
Medical IT Power Compatible
Designed for IPS, IMD, and medical power distribution systems.
IEC 61558 Compliance & Testing

Designed and tested as per IEC 61558 requirements for safety isolating transformers used in medical locations.

Tests Performed
Insulation Resistance Test
Applied Voltage (Hi-Pot) Test
No Load Test
Load Loss Test
Voltage Regulation Verification
Temperature Rise Test
Winding Resistance Measurement
Polarity & Vector Verification
Leakage Current Verification
Functional Testing with Medical Isolation Panels
Benefits of Low Leakage Current
Reduces risk of electric shock
Enhances patient safety
Prevents micro-shock hazards
Supports uninterrupted surgical procedures
Improves reliability of patient-connected equipment
Complies with hospital safety standards
Benefits in Operation Theatres (OT)
Protects Human Life During Surgery
Ensures Continuous Operation of Critical Equipment
Prevents Procedure Interruptions
Improves Diagnostic Accuracy
Reduces Electrical Noise
Maintains Power During First Earth Fault
Supports Hospital Electrical Safety Compliance
Applications
Operation Theatres (OT)
Intensive Care Units (ICU)
Emergency & Trauma Care
Diagnostic Imaging Centers
Cardiac Cath Laboratories
Neurology & Brain Monitoring
Recovery & Critical Care
Medical Laboratories
Healthcare Research Facilities

WHY CHOOSE MAGNETIC AND CONTROLS?

Healthcare Specialists
IEC 61558 Certified
Ultra-Low Leakage
Reliable & Durable
Custom Solutions

Need the right medical isolation transformer
for your application?

Our engineers are ready to help you find the perfect solution for your healthcare facility.