MEDICAL ISOLATION
TRANSFORMERS

Specially engineered for hospitals, operation theatres, ICUs, cath labs, and critical healthcare facilities. Delivers complete galvanic isolation with ultra-low leakage current for maximum patient and operator safety.

Medical Isolation Transformer

SPECIFICATIONS

KVA Rating
1 KVA to 100 KVA
Core Type
Low-Loss CRGO Core
Copper Windings
Input
Single Phase / Three Phase
230 V / 415 V
Insulation Class
Class H – 180°C
Leakage Current
< 0.5 mA (IEC 61558)
Temperature Rise
80°C Rise
Phase
Single Phase / Three Phase
Standard
IEC 61558-2-15
Indoor Installation

KEY FEATURES

01
Ultra-Low Leakage Current
Achieves < 0.5 mA leakage, minimizing electric shock risk.
02
Complete Galvanic Isolation
Full electrical separation between utility and medical equipment.
03
Enhanced Patient Protection
Protects patients connected to devices from hazardous touch voltages.
04
Superior EMI/RFI Suppression
Minimizes electromagnetic interference affecting sensitive equipment.
05
High Reliability Construction
Low-loss CRGO cores, copper windings, Class H Insulation.
06
Medical IT Power Compatible
Designed for IPS, IMD, and medical power distribution systems.
IEC 61558 Compliance & Testing

Designed and tested as per IEC 61558 requirements for safety isolating transformers used in medical locations.

Tests Performed
✓ Insulation Resistance Test
✓ Applied Voltage (Hi-Pot) Test
✓ No Load Test
✓ Load Loss Test
✓ Voltage Regulation Verification
✓ Temperature Rise Test
✓ Winding Resistance Measurement
✓ Polarity & Vector Verification
✓ Leakage Current Verification
✓ Functional Testing with Medical Isolation Panels
Benefits of Low Leakage Current
✓ Reduces risk of electric shock
✓ Enhances patient safety
✓ Prevents micro-shock hazards
✓ Supports uninterrupted surgical procedures
✓ Improves reliability of patient-connected equipment
✓ Complies with hospital safety standards
Benefits in Operation Theatres (OT)
• Protects Human Life During Surgery
• Ensures Continuous Operation of Critical Equipment
• Prevents Procedure Interruptions
• Improves Diagnostic Accuracy
• Reduces Electrical Noise
• Maintains Power During First Earth Fault
• Supports Hospital Electrical Safety Compliance
Applications
• Operation Theatres (OT)
• Intensive Care Units (ICU)
• Emergency & Trauma Care
• Diagnostic Imaging Centers
• Cardiac Cath Laboratories
• Neurology & Brain Monitoring
• Recovery & Critical Care
• Medical Laboratories
• Healthcare Research Facilities

WHY CHOOSE MAGNETIC AND CONTROLS?

Healthcare Specialists
IEC 61558 Certified
Ultra-Low Leakage
Reliable & Durable
Custom Solutions

Need the right medical isolation transformer
for your application?

Our engineers are ready to help you find the perfect solution for your healthcare facility.